Ul design i504 - In today’s highly competitive marketplace, it is crucial for businesses to prioritize the safety and compliance of their products. One way to achieve this is through UL testing ser...

 
Solar Aircraft Design - Solar aircraft design is explained in this section. Learn about solar aircraft design. Advertisement Solar airplanes don't have much on board. They're ridic.... Taylor swifts latest album

Design & Resource Center / Literature & Technical Guides / The PURPLE Book® Detailed drawings and assemblies. Find commercial construction details including wall assemblies. The PURPLE Book II. PDF. General Information. PDF. Steel Stud Partitions. PDF. Shaftwall Assemblies. PDF. Stair Shaftwall Details. PDF.Section 703.2.3 of the International Building Code (IBC) specifies that fire-resistance-rated assemblies tested in accordance with ASTM E119 or UL 263 are not to be considered to be restrained unless evidence satisfactory to the building official is furnished by the registered design professional showing that the construction qualifies for a restrained …Instructions. These instructions apply to 1 1⁄2 hour rated Ruskin combination fire smoke dampers and fire dampers mounted horizontally in design I503 as detailed in the UL Fire … Revit, CAD, and construction details for fire rated wall assemblies can be downloaded for planning and material estimation. Blog Careers Where to Buy. Data Sheets FAQs Technical Support. Connect with us. Tel: 317-398-4434 Fax: 317-398-3675 Sales: 800-825-4434 ext. 8576. Fire Rating. 1 hours. System STC. 61. System Thickness. 9.5 in. CAD/Revit & Acoustics. Revit PDF. Visit UL U493 on the UL website.Design & Resource Center / Literature & Technical Guides / The PURPLE Book® Detailed drawings and assemblies. Find commercial construction details including wall assemblies. The PURPLE Book II. PDF. General Information. PDF. Steel Stud Partitions. PDF. Shaftwall Assemblies. PDF. Stair Shaftwall Details. PDF.This new assembly, known as UL W404 contains several prominent attributes and increases the total number of fire resistive assemblies sponsored by MBMA to 13. UL W404 preserves the most common and efficient metal building system construction practices of the industry in this new 1-hr non-loadbearing exterior wall system. Wall Assemblies. USG provides resources here for our UL wall assemblies for seamless integration into any construction project. These wall assembly files are used for planning and estimation purposes for many UL wall types, such as fire-rated wall assemblies. Roof-Ceiling Assemblies. Helpful documents and resources for USG’s roof assemblies can be found on this page. Refer to our roof-ceiling assembly documents, which includes UL fire-rated roof assemblies, for easy guidance through the assembly of a roof or ceiling on your next project. Otherwise check out UL-I504 and I-501, they may or may not work in your application as the requirements are complex, very specific yet somewhat vague. Note: I don't have any …UL 2900- 2-1. Software Cybersecurity for Network-Connectable Products, Part 2-1: Particular Requirements for Network Connectable Components of Healthcare and Wellness Systems / Cybersécurité des logiciels pour les produits à connexion réseau, partie 2-1 : exigences particulières pour les composants à connexion réseau des systèmes de soins de santé et …UL FIRESTOP PENETRATION NUMBERING (Tested to UL 1479 Inspect to ASTM E-2174) SYSTEM First Alpha Character Letter Description C Systems intended to protect penetrations through either floors or walls F Systems intended to protect penetrations through floors W Systems intended to protect penetrations through walls ...Modern Design. UL Product iQ marries the longstanding UL safety certification information relied upon by millions of users with the intuitive design and user-friendliness of a modern search engine. Log In Register For Free. ... UL is committed to meeting our customers’ needs. Understanding who is accessing UL certification data and how the ...Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification such as Canada respectively. Zinc fingers are Å from K504 Fig. For 1-hour assemblies National Gypsum developed UL design I504 which is a 1-hour horizontal assembly that consists of 3-58 steel studs 16 oc. Ul Design K504.GCP DESIGN SELECTION PROGRAM. This program is designed to assist the user in selecting the optimum GCP Applied Technologies Fire Resistance Design based on specific project criteria. It is intended for use in the US market and those markets that utilize the International Building Code (IBC). The program is not intended to provide Fire ...We would like to show you a description here but the site won’t allow us.UL I503 design provides mechanical engineers and contractors with an alternative method of construction for the top or bottom of rated shaft penetrations whe...Instructions. These instructions apply to 1 1⁄2 hour rated Ruskin combination fire smoke dampers and fire dampers mounted horizontally in design I503 as detailed in the UL Fire …Solar Aircraft Design - Solar aircraft design is explained in this section. Learn about solar aircraft design. Advertisement Solar airplanes don't have much on board. They're ridic...For 1-hour assemblies National Gypsum developed UL design I504 which is a 1-hour horizontal assembly that consists of 3-58 steel studs 16 oc. Ul Design K504 122 PDF Ul Design K504 The Gypsum Construction Handbook-RSMeans 2009-01-03 One of the construction industrys longest-running most relied-on references The Gypsum …Dec 1, 2017 · More designs added to the fire and sound selector, including: a 1-hour ceiling membrane (UL Design I504), a 3-hour area separation wall (UL Design W454) and a 1-hour rated floor-ceiling assembly using SoundBreak ® XP ® (UL Design M514). A new section identifying the UL-Core designation of all NGC gypsum board products. Detail No. Title UL Design Head of Wall Firestop System Page SW Series - Shaftwall Assemblies 09 21 16.23 1 Hour Shaftwall Partition to Steel Beam 1 Hour Shaftwall Partition Offset from Beam SW 102 SW 103 U499, W419 U499, W419 U499, W419 U499, W419 SW 104 SW 105 1 Hour Shaftwall with Deflection Track 1 Hour Shaftwall with Deflection Track Design Studio & Tools. Design Studio Design Studio. Wall Assemblies; Floor-Ceiling Assemblies; ... (UL Type USGSP) Structo-Crete® Brand Structural Panels; Layer 4 - Steel Joists: 1 layer Channel-Shaped, 10" Deep Min., 16 Ga., Spaced 24" Max. O.C. Layer 5 - Clip Angles (Not Shown): 1 layer One Clip Angle Per Joist End; One Clip Angle per Joist ...A his and her closet can be a big issue for some couples. With the right design, those fights can be ended. Learn more. Advertisement Since men and women are quite different in ap... Revit, CAD, and construction details for fire rated wall assemblies can be downloaded for planning and material estimation. Blog Careers Where to Buy. Data Sheets FAQs Technical Support. Connect with us. Tel: 317-398-4434 Fax: 317-398-3675 Sales: 800-825-4434 ext. 8576. UL 2900- 2-1. Software Cybersecurity for Network-Connectable Products, Part 2-1: Particular Requirements for Network Connectable Components of Healthcare and Wellness Systems / Cybersécurité des logiciels pour les produits à connexion réseau, partie 2-1 : exigences particulières pour les composants à connexion réseau des systèmes de soins de santé et …ETL listing means that Intertek has determined a product meets ETL Mark safety requirements.. UL listing means that Underwriters Laboratories has determined a product meets UL Mark...Title: UL Design No. L501 Author: Powers Created Date: 3/26/2007 12:49:18 PMDesign Thicknessb Minimum Thickness Style in. mils in. mils ga. CH, ES 0.0188 18 0.0179 18 25 JR 0.0239 22 0.0227 23 24 CH, ES, JR, JS 0.0359 33 0.0341 34 20 Structural Properties–Steel Framing Components Component Product Average Weight Area Ix Sxc Allowance DesignPlease refer to UL design I504. What is the difference between restrained and unrestrained systems? UL publishes an A.E.C. Resources FAQ resource that includes an overview of …Design Studio Design Studio. Wall Assemblies; Floor-Ceiling Assemblies; Roof-Ceiling Assemblies; Design Details; Shaft Wall Limiting Heights & Spans; Competitor Comparison Tool; USG Sustainability Tool; USG Ceiling Technix™ Virtual Acoustics Experience™ (VAE) USG Assembly Builder™ All Design StudioIn today’s fast-paced world, product safety and compliance are of utmost importance. UL (Underwriters Laboratories) testing services play a crucial role in ensuring that products m...5. Furring Channels — No. 25 MSG galv steel, 2-7/16 in. or 2-9/16 in. or 2-23/32 in. wide at top and 1-7/16 in. wide at bottom by 7/8 in. deep; spaced at 24 in. O.C. perpendicular to joists except at wallboard end joints as noted below. Additional channel 75 in. long, positioned at each end joint of wallboard, 2-1/2 in. O.C. from the continuous … Wall Assemblies. USG provides resources here for our UL wall assemblies for seamless integration into any construction project. These wall assembly files are used for planning and estimation purposes for many UL wall types, such as fire-rated wall assemblies. UL I503 design provides mechanical engineers and contractors with an alternative method of construction for the top or bottom of rated shaft penetrations whe...installation and use of UL Listed or Classified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. Overview. Sheetrock® Brand Firecode® X Panels (UL Type SCX) are 5/8 in. (15.9 mm) Type X gypsum panels that feature a noncombustible gypsum core that is encased in 100% recycled face and back papers that form a high strength composite design. The face paper is folded around the long edges to reinforce and protect the core, and the ends are ... Floor-Ceiling Assemblies. Here, you can find drawings for our UL fire-rated floor assemblies and UL fire-rated ceiling assemblies. Our range of drawings can help pros plan projects …We would like to show you a description here but the site won’t allow us.Ready to use. Material Design. components. Material UI is an open-source React component library that implements Google's Material Design. It's comprehensive and can be used in production out of the box. Get started View templates. $ npm install @mui/material @emotion/react @emotion/styled.Method (e.g., Working Stress Design Method). For jurisdictions employing the Limit States Design Method, such as Canada, a load restriction factor shall be used — See Guide BXUV or BXUV7 * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.V438 | This UL design has multiple installation options for 1- to 4-hr. fire ratings. The assembly is tested with 25-gauge steel studs at 24” o.c. All UL-approved partition designs are minimum requirements. This means a tighter stud spacing, a heavier gauge or a wider stud is allowed per UL “ Guide Information for Fire-resistance Ratings .”.and UL Fire Ratings The following table lists the USG panels that are appropriate to use for different UL fire-resistive Designs. USG Panels USG Panels USG Panels UL Design Number UL Design Number UL Design Number G503, G531, L501, L508, N501, N502, N505, P515, P516, U026, U301, U302, U303, U304, U305, U308, U314, U321, U329, …UL I503 design provides mechanical engineers and contractors with an alternative method of construction for the top or bottom of rated shaft penetrations whe... Fire Rating. 1 hours. System STC. 39. System Thickness. 4.625 in. CAD/Revit & Acoustics. Revit PDF. Visit UL U415 UL System A on the UL website. Looka Logo Maker combines your logo design preferences with Artificial Intelligence to help you create a custom logo you'll love. All it takes is a few clicks and five minutes. Let's make a logo! 01. Our logo maker is easy. Start by entering your company name and industry, then select the perfect logo styles, colors, and symbols that you like ...Building Products and Systems. You can rely on UL Solutions' safety science leadership to help solve your safety, quality assurance and compliance challenges. Our comprehensive inspection, validation and certification services for the building and construction products industry help you bring products and systems to market quickly and cost ...Design No. U305 October 06, 2020 Bearing Wall Rating — 1 Hr Finish Rating — See Items 3, 3A, 3D, 3E, 3F, 3G, 3H, 3J and 3L. STC Rating - 56 (See Item 9) This design was evaluated using a load design method other than the Limit States Design Method (e.g., Working Stress Design Method). For jurisdictions employing the Limit StatesUSE IN UL CLASSIFIED SYSTEMS (GA-605) Rev. June 13, 2014 The Fire Resistance Directory published by Underwriters Laboratories Inc. lists gypsum panel products that are classified for fire resistance under category “Gypsum Board (CKNX).” Each UL Design lists the specific manufacturers and products that are suitable for use in the design.Certification Information. Product iQ is UL Solutions' online location for certification information. It combines data from many legacy UL solutions, including the Online …This design saves space but is more labor intensive. (Reference page 14 in The PURPLE Book® .) 1-hour fire-rated wall: Apply three layers of ⅝" Type X gypsum board on one side. 2-hour fire-rated wall: Apply four layers of ⅝" Type X gypsum board to one side. The details below show options for building UL design V497.Design Studio Design Studio. Wall Assemblies; Floor-Ceiling Assemblies; Roof-Ceiling Assemblies; Design Details; Shaft Wall Limiting Heights & Spans; Competitor Comparison Tool; USG Sustainability Tool; USG Ceiling Technix™ Virtual Acoustics Experience™ (VAE) USG Assembly Builder™ All Design StudioGCP Applied Technologies Inc., 2325 Lakeview Parkway, Suite 400, Alpharetta, GA 30009, USA GCP Canada, Inc., 294 Clements Road, West, Ajax, Ontario, Canada L1S 3C6Return to results :: Keyword: "I504" Wallboard. UL Certified. DOCUMENT: CKNXC.R2717 · Product Code (UL CCN): CKNXC The document listing is represented by a combination of the UL CCN and File Number. A UL CCN (Category Control Number) is the code that represents the Product Category (Category Description). See below for more info on …Since 1973, model building codes such as the IBC and the NEC have referenced the GA-600 Fire Resistance and Sound Control Design Manual as a primary source of fire resistant and sound control rated designs. The 2021 edition contains more than 750 fire- and sound-rated systems including: Walls and interior partitions Shaft walls and …Title: BXUV.V438 - Fire Resistance Ratings - ANSI/UL 263 Author: jwarren Created Date: 3/18/2016 8:05:02 AM6 CGC Fire-Resistant Assemblies Test Certification Test Conditions and Fire and sound tested assemblies listed in this Selector are based on characteristics, properties and performance Certification of materials and systems obtained under controlled test conditions as set forth in the appropriate ULC and ASTM Standards in effect at the time of test. …UL Type Designations; Material Estimators Material Estimators. Sheetrock® Wallboard Estimator; Ceilings Materials Estimator; ... All Design Studio & Project Tools. Inspiration. Project Gallery Project Gallery. Brock Commons, University of British Columbia Case Study; The Bow Tower;The BXUV Guide Information provides valuable information and guidance on considerations associated with the (BXUV) fire-resistance rated designs, some of which provide acceptable variations to the details included in individual designs. “Luminaires (light fixtures) may be installed individually or end to end (in rows). Otherwise check out UL-I504 and I-501, they may or may not work in your application as the requirements are complex, very specific yet somewhat vague. Note: I don't have any experience with mezzanine design. UL Design. <img height="1" width="1" style="display: none" src="https://www.facebook.com/tr?id={your-pixel-id-goes-here}&ev=PageView&noscript=1" /> <link rel="stylesheet" href ...Compliance solutions for buildings, products, systems, and designs to meet fire regulations. Fire-rated wall, floor and ceiling assemblies provide the necessary fire and smoke …CGC Ceiling Systems - Version One. The UL assembilies listed below are Cretified for use in Canada by UL and comply with CAN/ULC S101 for fire resistence. The Standards …Oct 6, 2020 · Design No. U305 October 06, 2020 Bearing Wall Rating — 1 Hr Finish Rating — See Items 3, 3A, 3D, 3E, 3F, 3G, 3H, 3J and 3L. STC Rating - 56 (See Item 9) This design was evaluated using a load design method other than the Limit States Design Method (e.g., Working Stress Design Method). For jurisdictions employing the Limit States For 1-hour assemblies National Gypsum developed UL design I504 which is a 1-hour horizontal assembly that consists of 3-58 steel studs 16 oc. Ul Design K504 122 PDF Ul Design K504 The Gypsum Construction Handbook-RSMeans 2009-01-03 One of the construction industrys longest-running most relied-on references The Gypsum …Best Job Ever: AWCI Contractors Reveal Their Best Work. Rob Aird, C. Brent Allen, Lee Zaretzky, Davis Sprague and Travis Vap share a passion for transforming spaces and structures with an eye for craftsmanship, innovation …In today’s fast-paced world, product safety and compliance are of utmost importance. UL (Underwriters Laboratories) testing services play a crucial role in ensuring that products m... 1. UL tests rate an entire assembly. No ceiling or suspension system product alone constitutes a fire-rated assembly. 2. You can use only the specific type, size, and minimum thickness of Fire Guard™ ceilings or suspension system identified in each assembly. 3. This table is a guide. (See UL Fire Resistance Directory for complete design details). If you have any questions, please reach out to our customer service team at 1-800-879-8000 (US) or 1-800-363-4458 (Canada) for assistance. Fire Protection Design Team. Hilti North America. 3701 W. Royal Lane, Suite 100, Irving, TX 75063. P 1-800-879-8000 I F 918-254-1679. UL Category Control No. UL File No. UL Category Control No. Description UL 508A Paragraph(1) Representative Photo Bulletin Number Description Web link UL 508 NKJH E205542 Combination Motor Controller 30.1.5 31.1.4 33.1.1 34.1.1 140M • Self-protected combination motor controllers • Provide disconnect, overcurrent protection, …Design No. I504 | PDF | Drywall | Framing (Construction) I504_20220719 - Free download as PDF File (.pdf), Text File (.txt) or read online for free. UL Details.Weyerhauser I-Joist Evaluation Report ESR-1153-23. PDF. Find required Certified ICC and UL evaluation reports for National Gypsum products and systems assemblies.Instructions. These instructions apply to 1 1⁄2 hour rated Ruskin combination fire smoke dampers and fire dampers mounted horizontally in design I503 as detailed in the UL Fire …Fire-Rated Assemblies in Commercial Construction - Free download as PDF File (.pdf), Text File (.txt) or read online for free. Construction wall details.2. OPENING PROTECTIVES. A. FIRE-RESISTANCE RATED GLAZING Fire-resistance rated glazing tested as part of a fire-resistance rated wall assembly in accordance with the Standard for Fire Tests of Building Construction and Materials, UL 263 (ASTM E119), is covered under the Fire-resistance Rated Glazing Materials category.These materials are … It combines data from many legacy UL solutions, including the Online Certification Directory, Product Spec and several iQ databases into one streamlined experience. A free Product iQ account helps users verify UL certification of products and components, locate UL Solutions guide information and search for alternative certified products. It combines data from many legacy UL solutions, including the Online Certification Directory, Product Spec and several iQ databases into one streamlined experience. A free Product iQ account helps users verify UL certification of products and components, locate UL Solutions guide information and search for alternative certified products.We would like to show you a description here but the site won’t allow us.Design Studio & Tools. Design Studio Design Studio. Wall Assemblies; Floor-Ceiling Assemblies; ... (UL Type USGSP) Structo-Crete® Brand Structural Panels; Layer 2 - Steel Joists: 1 layer 8" Min. Deep, 16 ga., Spaced 24" Max. O.C. Layer 3 - Clip Angles (Not Shown): 1 layer One Clip Angle Per Joist End; One Clip Angle per Joist End ...Since 1973, model building codes such as the IBC and the NEC have referenced the GA-600 Fire Resistance and Sound Control Design Manual as a primary source of fire resistant and sound control rated designs. The 2021 edition contains more than 750 fire- and sound-rated systems including: Walls and interior partitions Shaft walls and …A his and her closet can be a big issue for some couples. With the right design, those fights can be ended. Learn more. Advertisement Since men and women are quite different in ap...Method (e.g., Working Stress Design Method). For jurisdictions employing the Limit States Design Method, such as Canada, a load restriction factor shall be used — See Guide BXUV or BXUV7 * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.5. Furring Channels — No. 25 MSG galv steel, 2-7/16 in. or 2-9/16 in. or 2-23/32 in. wide at top and 1-7/16 in. wide at bottom by 7/8 in. deep; spaced at 24 in. O.C. perpendicular to joists except at wallboard end joints as noted below. Additional channel 75 in. long, positioned at each end joint of wallboard, 2-1/2 in. O.C. from the continuous …installation and use of UL Listed or Classified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements.In today’s fast-paced world, product safety and compliance are of utmost importance. UL (Underwriters Laboratories) testing services play a crucial role in ensuring that products m...UL I503 design provides mechanical engineers and contractors with an alternative method of construction for the top or bottom of rated shaft penetrations whe...National Gypsum Purple Book - Fire-Rated Assemblies in Commercial Construction - BuildSite. This pdf provides detailed information and illustrations of various fire-rated …Solar Aircraft Design - Solar aircraft design is explained in this section. Learn about solar aircraft design. Advertisement Solar airplanes don't have much on board. They're ridic... Wall Assemblies. USG provides resources here for our UL wall assemblies for seamless integration into any construction project. These wall assembly files are used for planning and estimation purposes for many UL wall types, such as fire-rated wall assemblies. in the individual U400 or V400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following ... number of layers and fasteners as required in the individual Wall and Partition Design. Max size of opening is 9,800 in 2 (6.32 m ) with a max dimension of 100 in. (254 cm). The hourly F Rating of the firestop ...Construction Design. Pat Grotlisch. Phone: (310) 889-8287 Email . Construction Design. Amy Hockett. National Marketing Manager, Architectural Services. Phone: 704-365-7931 Email Amy Hockett Jordy Polk. Technical Marketing Specialist. Phone: 704-365-7477 Email Jordy Polk National Accounts.

Weyerhauser I-Joist Evaluation Report ESR-1153-23. PDF. Find required Certified ICC and UL evaluation reports for National Gypsum products and systems assemblies. . Ochsner.org

ul design i504

Need a print design company in Dubai? Read reviews & compare projects by leading print designers. Find a company today! Development Most Popular Emerging Tech Development Languages...can you use pulp riot blank canvas on wet hair. kalamazoo police shooting; did bridges of madison county win any awards; fire in oxford ma todayOne-Hour Wall Membrane (Based on UL Design U 301) The membrane consists of two layers of 5/8” (15.9 mm) type X gypsum board directly applied to framing or furring. The base layer of gypsum board is applied either parallel or at right angles to wall or partition framing 16” (406 mm) o.c. and attached with 1” (25 mm) Type S or S-12 drywall ...Call our technical support team at 800.USG.4YOU (874.4968) Sheetrock® Brand EcoSmart Panels Firecode® X (UL Type ULIX™) are lightweight 5/8 in. (15.9 mm) enhanced proprietary Type X gypsum panels that have been formulated to achieve all of the same strength and performance characteristics as standard 5/8 in. (15.9 mm) Sheetrock® …• ™e Fir Guard components meet broad range of UL® design assemblies (XL7936G90 is not fire rated) • 10-Year Limited System Warranty, 30-Year Limited Ceiling Systems Warranty • G90 hot-dipped galvanized coating is available for exterior applications (HD8906G90, XL8945PG90, XL8947PG90, XL8965G90, XL7936G90) CGC Ceiling Systems - Version One. The UL assembilies listed below are Cretified for use in Canada by UL and comply with CAN/ULC S101 for fire resistence. The Standards Council of Canada recognizes UL as an accredited testing and cerification organization for certification of materials and systems to Canadian standards. Title: BXUV.V438 - Fire Resistance Ratings - ANSI/UL 263 Author: jwarren Created Date: 3/18/2016 8:05:02 AMElements of buildings the fire-resistance rating classifies the ability of an assembly to confine and isolate fire within a zone comprised of fire-resistance rated walls ceiling and floor assemblies. For 1-hour assemblies National Gypsum developed UL design I504 which is a 1-hour horizontal assembly that consists of 3-58 steel studs 16 oc. 608 ... USE IN UL CLASSIFIED SYSTEMS (GA-605) Rev. June 13, 2014 The Fire Resistance Directory published by Underwriters Laboratories Inc. lists gypsum panel products that are classified for fire resistance under category “Gypsum Board (CKNX).” Each UL Design lists the specific manufacturers and products that are suitable for use in the design. A: Yes, fire-rated roof-ceiling assemblies that include resilient channels and loose-fill insulation are a common option that allow insulation to rest directly against …Title: FIRE-RESISTANCE RATINGS - ANSI/UL 263 | UL Product iQ Author: ctallen Created Date: 5/7/2019 4:29:04 PMReady to use. Material Design. components. Material UI is an open-source React component library that implements Google's Material Design. It's comprehensive and can be used in production out of the box. Get started View templates. $ npm install @mui/material @emotion/react @emotion/styled.Contact our technical services department at. 1-888-834-2371, or email [email protected]. For additional information about these or other Thermafiber products contact us at 1-888-834-2371 or visit our website www.thermafiber.com.Please refer to UL design I504. What is the difference between restrained and unrestrained systems? UL publishes an A.E.C. Resources FAQ resource that includes an overview of …1. Search using specific parameters. To locate designs meeting your project specifications, follow the link to UL Product SpecTM. Select Products, Systems or Assemblies > ….

Popular Topics